Development of a new flexible manipulator for minimally invasive surgery

Completed

Development of a new flexible manipulator integrating contact force sensors and shape sensors for MIS (minimally invasive surgery).

There are a number of problems associated with the existing needle drivers and grippers for minimally invasive surgery. They are integrated into a rigid cylindrical hollow rod, so the workspace and maneuverability of those devices are limited when accessing small openings and narrow spaces in the body, and using them can result in damaging soft tissues and organs, so the patients may suffer from aftereffects following the surgery.

To overcome the barriers of such conventional medical devices, flexible manipulators have been developed. Although the workspace and maneuverability of the flexible manipulator outperform those of the conventional ones, there are further challenges to overcome: measuring its shape sensing, and its body force measurement. To facilitate shape sensing, different methods have been proposed by vision (camera) and Fiber Bragg Grating (FBG) for flexible manipulators.

The sensing performance is very accurate, but the device called “interrogator” which can detect strain values from the FBGs attached to the mechanical sensor flexure costs around £20000, and manufacturing the bending sensor is too complicated so that it spends a long time fabricating it. Moreover, it is required for electrical noise filtering and temperature compensation, and the maximum measurable sensing frequency ranges are limited up to 50 Hz.

In some devices, the body force sensors have been integrated into each of the manipulator’s joints. Depending on the manipulator’s shapes, the sensors measure external forces and internal forces (caused by wires or air pressure), with the external force decoupled by a mechanical mathematic model. However, decoupling the external force is quite complicated because the mathematical model is not always predictable.

The geometry of conventional force/torque sensors is not suitable to be integrated into the flexible manipulator since they have no ample space allowing wires or pipes to be passed through it.

For these reasons, in this project, we have set out to develop a new flexible manipulator integrating contact force sensors and shape sensors using optoelectronic sensors. The main advantage of these contact force and shape sensors is that they can measure bending angles (shapes) and external force values very accurately, and at very little cost, and are simple to manufacture. Furthermore, they are very stable with a maximum measurable sensing frequency of more than 10 kHz, and low electrical noise.

This technology has also been adopted to work with shape sensing applications for haptic gloves and rehabilitation devices.

Development of a new flexible manipulator for minimally invasive surgery
Development of a new flexible manipulator for minimally invasive surgery
Development of a new flexible manipulator for minimally invasive surgery

Publications

  • Osman, W. Li, X. Du, T. Minton, Y. Noh, Prototype of Optoelectronic Joint Sensor Using Curvature Based Reflector for Body Shape Sensing, IEEE International Conference on Wearable and Implantable Body Sensor Networks (BSN’22), July 2022 (Accepted).
  • D. Osman, W. Li, X. Du, T. Minton, Y. Noh, Miniature Optical Joint Measurement Sensor for Robotic Application Using Curvature Based Reflecting Surfaces, IEEE Sensors Letter, 2022; DOI: 10.1109/LSENS.2022.3169915
  • D. Osman, X. Du, W. Li, Y. Noh, Development of an Optical Shape Sensing Method using Optoelectronic Sensors for Soft Flexible Robotic Manipulators in MIS, IEEE Transactions on Medical Robotics and Bionics, 2022; DOI:10.1109/TMRB.2022.3155200
  • B. He, M. Li, Z. Liang, W. Yao, S. Sareh, J. Xie, G. Xu, Y. Noh, Optoelectronic-based pose sensing for a hand rehabilitation exoskeleton continuous structure, IEEE Sensors Journal, 2022; DOI: 10.1109/JSEN.2022.3147227.
  • W. Lee, Y. Noh, B. Shin, Y. Kim, Feedback Control of Miniaturized Oscillatory Electromagnetic Actuators Using Tiny Optoelectronic Sensor, Transactions of the Korean Society of Mechanical Engineers – A, vol.45, no.5, pp. 361-366, 2021; DOI: 10.3795/KSME-A.2021.45.6.515
  • D. Osman; X. Du; W. Li; Y. Noh, An Optical Joint Angle Measurement Sensor based on an Optoelectronic Sensor for Robot Manipulators, 2020 8th International Conference on Control, Mechatronics and Automation (ICCMA), 2020; DOI: 10.1109/ICCMA51325.2020.9301526.
  • J. H. B. Koh, T. Jeong, S. Han, W. Li, K. Rhode, Y. Noh, Optoelectronic Sensor-Based Shape Sensing Approach for Flexible Manipulators, IEEE Engineering in Medicine and Biology Conference (EMBC), pp.3199-3203, 2019; DOI: 10.1109/EMBC.2019.8856882.
  • Y. Noh, S. Han, P. Gawenda, W. Li, S. Sareh, K. Rhode, Contact Force Sensor based on S-shaped Beams and Optoelectronic Sensors for Flexible Manipulators for Minimally Invasive Surgery (MIS), IEEE Sensor Journal, pp.3487-3495, 2019; DOI: 10.1109/JSEN.2019.2945163.
  • Y. Noh, P. Gaweda, M. Street, G. Lawrence, S. Han, W. Lin, J. Fras, K. Althoefer, K. Rhode, Contact force sensors measuring tangential force components for flexible manipulators, The 2nd IEEE UKI RAS Conference, 2018.
  • T. Jeong, Y. Noh, S. Han, K. Rhode, Shape sensing using optoelectronic sensors for flexible manipulators, The 2nd IEEE UKI RAS Conference, 2018.

Awards

[1] “Joint runner up award”, the 2nd IEEE UK and Ireland RAS conference 2018.


Meet the Principal Investigator(s) for the project

Dr Yohan Noh
Dr Yohan Noh - He received his first B.Sc. degreefrom the Department of Mechanical Engineering, Seoul National University of Scienceand Technology, Korea (2002) and his second B.Sc. degree from the Department ofElectrical Engineering from Yonsei University, Korea (2004). He did his M.Sc. and Ph.D. atthe Department of Science and Engineering (robotics), Waseda University, Tokyo, Japan in2007 and 2011, respectively. After this, he worked as a research associate in Roboticswithin the Department of Biomedical Engineering and Informatics, King's College London.During his PhD and Postdoctoral studies in the UK and Japan, he studied and proposed agreat number of the robotic systems for use in medicine and healthcare in Japan, Korea,and the UK. His work has resulted in more than seventy peer-reviewed papers includingsixteen journal papers and more than seventy papers in top journals and conferences ofrobotics. He has eleven published patents so far.He has been fortunate to have the opportunity of involvement in commercialisationprocess of a number of joint projects between academia and industry. Being ambitious tolay out a research direction which considers commercialisation of the developed system inthe beginning of a project, led to successful commercialisation of the projects and therespective products are now being sold in international market.He has facilitated many collaborative activities between robotics groups in the UK, EU, andJapan through domestic and international joint projects (EU-project STIFF-FLOP, Grant No.287728), (Wellcome Trust IEH project iFIND, Grant No.102431), and (Robotics AdvancedMedical Cluster, Japan), and have been an active member of the robotics community (IEEERAS, EMBS, ASME, RSJ, JSCAS), and helped in the organisation of RSJ, ROMANSY, ICCAS,ROBIO, ICRA, and EMBC conferences since 2008.

Related Research Group(s)

robot lab

Robotics and Automation - We carry out world-class research in robotics and autonomous systems, exploiting and exploring opportunities to develop innovative solutions for industrial and societal applications.

machine digital (3)

Digital Manufacturing - Being at the forefront of solutions for building smart machines, we create an operational framework for the digital transformation to Industry 4.0.


Partnering with confidence

Organisations interested in our research can partner with us with confidence backed by an external and independent benchmark: The Knowledge Exchange Framework. Read more.


Project last modified 22/11/2023